Can you get a false high blood pressure reading?

Acute meal ingestion, caffeine or nicotine use can all negatively affect BP readings, leading to errors in measurement accuracy. If the patient has a full bladder, that can lead to an error in systolic BP of between 4 mm Hg and 33 mm Hg, compared with the white-coat effect can have an error of up to 26 mm Hg.

Which food adds more sperms?
Which food adds more sperms?

Which are the Food Items That Boost Sperm Count and Improve Quality? Foods that can Boost Sperm Count. There are a lot of foods that can boost...

Read More »
How do guys get prostatitis?
How do guys get prostatitis?

Bacterial prostatitis is caused by a bacterial infection in the prostate. Bacteria can get into the prostate when infected urine flows backwards...

Read More »

Accurate and reliable blood pressure (BP) measurement is critical for the proper diagnosis and management of hypertension. So much so that a 5 mm Hg BP measurement error can lead to incorrect hypertension classification in 84 million individuals worldwide, according to a position statement published in the Journal of Hypertension. Understanding the ways BP measurement goes wrong, and how to tackle them, can improve diagnosis and management of hypertension. The AMA has developed online tools and resources created using the latest evidence-based information to support physicians to help manage their patients’ high BP. These resources are available to all physicians and health systems as part of Target: BP™, a national initiative co-led by the AMA and American Heart Association.

Related Coverage The one graphic you need for accurate blood pressure reading

Unfortunately, BP measurement is often suboptimally performed in clinical practice, which can lead to errors that inappropriately alter management decisions in 20% to 45% of cases. This inaccuracy has persisted despite extensive education and efforts to raise awareness on the adverse consequences of incorrect clinic BP measurement, according to the Lancet Commission on Hypertension Group position statement. That statement was co-written by AMA Vice President of Health Outcomes Michael Rakotz, MD, and Gregory D. Wozniak, PhD, who is director of outcomes analytics at the AMA. “Many measurement errors can be minimized by appropriate patient preparation and standardized techniques. Validated semi-automated or automated upper arm cuff devices should be used instead of auscultation to simplify measurement and prevent observer error,” the position statement says. The position statement cites multiple causes of inaccuracy in measurement. Here are four ways BP measurement goes wrong and how to address them.

Patient-related Patient-related

There are instances in which the BP-measurement error is caused by the patient. Acute meal ingestion, caffeine or nicotine use can all negatively affect BP readings, leading to errors in measurement accuracy. If the patient has a full bladder, that can lead to an error in systolic BP of between 4 mm Hg and 33 mm Hg, compared with the white-coat effect can have an error of up to 26 mm Hg. It is important for the patient to rest comfortably in a quiet environment for five minutes in a chair. The patient should also have an empty bladder and not have eaten, ingested caffeine, smoked or engaged in physical activity at least 30 minutes before the measurement.

Procedure-related Procedure-related

Can being hungry affect blood pressure?
Can being hungry affect blood pressure?

Can not eating cause your blood pressure to go lower or higher? Fasting can help lower blood pressure. It can also result in an electrolyte...

Read More »
How can I please my man with his prostate?
How can I please my man with his prostate?

A person can insert a clean, lubricated finger into the anus, with the finger pointing toward the naval. According to Planned Parenthood, the...

Read More »

Errors can also occur due to inaccuracies with the procedure. For example, having the patient’s arm lower than heart level can lead to an error of 4 mm Hg up to 23 mm Hg. Procedure related error might also occur if the patient’s legs are crossed at the knees or if the patient is allowed to talk during the BP measurement. A fast deflation rate also can harm accuracy.

Equipment-related Equipment-related

If a cuff is too small or too large, errors in measurement can occur. Adding to inaccuracy is automated device variability, which can account for average error in systolic BP of between -4 mm Hg and -17 mm Hg. “An important issue with automated devices is that many have not been clinically validated for measurement accuracy,” says the statement. “Clinical validation involves demonstrating that the device meets the accuracy requirements of international BP measurement standards.” The process of clinical validation involves performing a protocol-based comparison using multiple measurements against blinded, two-observer auscultatory reference standard. For greater accuracy, only validated devices should be used.

Physician- or health professional-related Physician- or health professional-related

One common error in the clinical setting is failure to include a five-minute rest period. Errors can also include talking during the measurement procedure, using an incorrect cuff size and failure to take multiple measurements. Time constraints are also quite common for casual measurements. This is because a casual reading takes about two minutes to perform compared with eight minutes for a standardized measurement. Physician readings were also found to be higher than nurse readings, which is the white coat effect in action. The physician, nurse or other health professional is responsible for performing proper BP measurement while ensuring—to the greatest extent possible—that all potential causes of inaccuracy are avoided. Training programs can lead to short-term success in BP readings. These can be web-based or in-person. However, shorter web-based programs are preferred because of their practical advantages, lower cost and scalability. Quality improvement programs that combine use of automated office BP measurement with physician and care team education on proper measurement, as well as advice on clinical workflow enhancement, can also improve readings.

Does peanut butter increase testosterone?
Does peanut butter increase testosterone?

Does Peanut increase testosterone? A. Yes, Peanuts have can increase testosterone levels. This quality is because peanuts contain arginine, which...

Read More »
Is pumpkin seed a DHT blocker?
Is pumpkin seed a DHT blocker?

Pumpkin seed oil scientifically proven to block DHT, while also stimulating the follicles and delivering nutrients to the scalp. This means that...

Read More »
Can you feel an enlarged prostate when sitting?
Can you feel an enlarged prostate when sitting?

Pain or burning during urination, which is much less common. Discomfort or pain when sitting, caused by an enlarged prostate.

Read More »
Do girls need a prostate?
Do girls need a prostate?

Have you ever wondered, “do women have prostates”? In short, the answer is no. The primary function of the male prostate is to secrete prostate...

Read More »